2 changes: 1 addition & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -399,7 +399,7 @@ is [`docs/changelog.md`](docs/changelog.md), dated and never rewritten.

**Every purchase still outstanding is in one place**, the roadmap's
[*Everything still to buy*](docs/roadmap.md#everything-still-to-buy):
12 items now, 0 later, and a rule that nothing joins them without a
10 items now, 0 later, and a rule that nothing joins them without a
decision. This sentence used to carry the list itself, name three purchases
coupled to the UPS work and omit the tier's host entirely, which is how one
ProDesk came to be bought for two jobs. It names no current item for the
Expand Down
31 changes: 31 additions & 0 deletions docs/changelog.md
Original file line number Diff line number Diff line change
Expand Up @@ -17,6 +17,37 @@ roadmap as it read that day, and the *Done* entries keep the shape they had
there. `check_docs.py` does not check this file, for the reason its module
docstring gives: it is a record, not a claim about now.

## 2026-10-15

- **The KVM goes on a shelf, and the console and power maps are decided**
([#919](https://github.com/Gerrrt/HomeLab/issues/919)). The screen, the
CRS326, `ifrit`'s Tiny mount, `trinity`'s tray and the keyboard drawer are
mounted. The drawer and the Tiny mount leave *Everything still to buy* by
its rule, so twelve rows become ten. Both maps are in
[`hardware.md`](hardware.md#console-and-power-maps).
- **The KVM's ears leave a gap.** The MT-VIKI 801UK-L is sold as a half-U
device, so its ears take two adjacent holes of a unit's three. The holes
are not evenly spaced, so any two adjacent ones put the chassis about
8 mm off centre. No two-hole ear can centre it. It goes on a third 1U
vented shelf at U23 instead, which takes all three holes and needs no
drilling. Drilled full-height ears and a full-1U replacement KVM were
weighed and declined: a drill for the one, a new switch and eight cable
sets for a cosmetic offset for the other.
- **KVM ports count in the power-up order** of the move runbook's §7,
since the switch selects port 1 at power-on and `morpheus` is the first
host brought up from the console: `morpheus`, `trinity`, `Saruman`,
`smaug` if its rear VGA is used, then `ifrit`. `smaug` is new to the
list: racked, it loses the monitor beside it.
- **PDU outlets follow the rack from the bottom up**, the external bricks
together at the far end where they only block each other. The number is
a label only; the rule is that a cord's outlet tells you its device. Both
laptops' chargers go on the UPS's own outlets beside the TP-Link, which
keeps the map the same whether the DL360 has one supply or two. One
check joins the runbook: which UPS outlet group feeds the PDU, and
whether that group's switching settings fit ADR-0049 and the power-up
order. No document records the groups.
- The switch's ports are not reordered: the captured map stands.

## 2026-10-14

- **`ifrit` arrived, and a VGA card for it was ordered**
Expand Down
61 changes: 58 additions & 3 deletions docs/hardware.md
Original file line number Diff line number Diff line change
Expand Up @@ -108,13 +108,13 @@ CRS326 with them.
| U | Device | Why here |
| --- | --- | --- |
| U25–U32 | ViewSonic N1700W on an 8U VESA rack mount | The very top. The console's height frees the middle of the rack for air between machines. Light, so high is fine |
| U24 | 1U sliding keyboard and mouse shelf | Directly under the screen, about 112 cm up |
| U23 | MT-VIKI 8-port KVM | Beside the console, so its console cables are short. It was at U6. Its lead sets reach the DL360 20 units down, checked 2026-10-12 |
| U24 | 1U sliding keyboard and mouse shelf | Directly under the screen, about 112 cm up. Mounted 2026-10-15 |
| U23 | MT-VIKI 8-port KVM, on a 1U vented shelf | Beside the console, so its console cables are short. It was at U6. Its lead sets reach the DL360 20 units down, checked 2026-10-12. The shelf is because the KVM is sold as a half-U device: its ears take two of a unit's three holes, and the holes are not evenly spaced, so it sits about 8 mm off centre whichever pair is used. The shelf takes all three. Decided 2026-10-15 |
| U22 | Vented blank, or left open | Air over the CRS326. It is passive, and two S+RJ10s side by side need "additional cooling" ([MikroTik's guidance](https://help.mikrotik.com/docs/spaces/ROS/pages/240156916/S+RJ10+general+guidance)) if the 2.5G WAN work goes ahead |
| U21 | MikroTik CRS326-24G-2S+RM (`neo`) | Replaces the MokerLink (#444). SFP+ 1–2 are the 2.5G path, if built. Racked 2026-10-12 |
| U20 | 1U horizontal cable manager | Strain relief between switch and panel. A tugged hand-crimped WAN plug was the slow internet #914 traced (#923) |
| U19 | Jadol 24-port patch panel | Next to the switch, so its patch cords stay short |
| U18 | 1U mount for a Lenovo ThinkCentre Tiny: `ifrit` | The offensive range (ADR-0007, ADR-0017), beside the other two 1-litre boxes. A Tiny is not a ProDesk Mini, so buy a mount made for the Tiny and check it fits before reusing `morpheus`'s tray design |
| U18 | 1U mount for a Lenovo ThinkCentre Tiny: `ifrit` | The offensive range (ADR-0007, ADR-0017), beside the other two 1-litre boxes. A Tiny is not a ProDesk Mini, so its mount is one made for the Tiny, not `morpheus`'s tray design. Mounted 2026-10-15 |
| U17 | *gap* | Keeps the range off the sensitive tier's box |
| U16 | ProDesk Mini tray: `trinity` | Off the shelf. Same tray as `morpheus`. Its 2 TB USB photo disk sits on the same tray |
| U15 | ProDesk Mini tray: `morpheus` | |
Expand All @@ -133,6 +133,61 @@ there is no headroom for another server. If the rack runs out, the 1U
console drawer below gives back eight units, or nine with a model that
replaces the KVM too.

#### Console and power maps

Decided 2026-10-15, cabled in the #919 window. Neither map existed before:
the move runbook asked for the KVM's to be written down at the rack. Both
are useful only to someone already standing at it, the same reach as the
cable colours [`security.md`](security.md) publishes.

**The KVM counts in the power-up order** of
[`move-into-the-32u-rack.md`](runbooks/move-into-the-32u-rack.md) §7. The
switch selects port 1 at power-on, and `morpheus` is the first host brought
up from the console.

| KVM port | Host | Why |
| --- | --- | --- |
| 1 | `morpheus`, U15 | First up; the console the house's DHCP depends on |
| 2 | `trinity`, U16 | Second up; where the passphrase prompt appears if the TPM does not unseal |
| 3 | `Saruman`, U3 | Third up; the iLO is the usual path and the KVM the fallback |
| 4 | `smaug`, U5–U9 | Racked, it loses the monitor beside it. Only if the TS150's rear VGA is used; check before cabling |
| 5 | `ifrit`, U18 | Off until the playground build |
| 6–8 | spare | |

**The PDU follows the rack from the bottom up, bricks at the far end.** It
is an unswitched strip, so the number is only a label, and the rule is that
a cord's outlet tells you its device. External bricks block their
neighbours, so they sit together at the high-numbered end.

| Outlet | Device |
| --- | --- |
| 1 | DL360, supply 1 |
| 2 | DL360, supply 2 if fitted, else spare |
| 3 | `smaug` |
| 4 | CRS326 |
| 5 | spare |
Comment thread
Gerrrt marked this conversation as resolved.
| 6 | `morpheus`'s brick |
| 7 | `trinity`'s brick |
| 8 | `ifrit`'s brick |
| 9 | The N1700W's 12 V brick |
| 10 | KVM |

**Both laptops' chargers go on the UPS's own outlets, beside the TP-Link
that feeds them**, not on the PDU. The runbook's §1.7 counts them as PDU
loads and says to move them to the UPS if the count reaches eleven; with
two DL360 supplies it does, and the laptops carry their own cells, so they
need the PDU's outlets least. Putting them there in either case keeps the
map the same whatever the DL360 turns out to have, and outlet 5 stays
spare.

**Which UPS outlet group feeds the PDU is not recorded.** The Smart-UPS X's
outlets are in groups the card can switch and sequence separately. Read
which group the PDU's cord is on, check that group's turn-off and turn-on
settings fit the shutdown in
[ADR-0049](adr/0049-shut-down-on-the-ups-from-a-nut-server-on-the-firewall.md)
and the power-up order in the runbook's §7, and write both here. The same
goes for the group the TP-Link and the chargers are on.

**`smaug` on its side, measured 2026-10-12.** Upright, the TS150 is 15"
tall, 7" wide and 17" deep, and weighs about 20 lb with its drives. On its
side the 7" becomes its height: 4U is exactly 7.00", so with a shelf tray
Expand Down
7 changes: 3 additions & 4 deletions docs/roadmap.md
Original file line number Diff line number Diff line change
Expand Up @@ -347,14 +347,13 @@ ADR set; its last two rows are what it still needs. On 2026-10-13 the move
into the 32U rack ([#919](https://github.com/Gerrrt/HomeLab/issues/919)) put
its parts here, which had been listed only in its runbook's §0.1, and
`Saruman`'s memory joined them. Already on hand, so not listed: the frame,
the VESA mount, `trinity`'s ProDesk tray and the velcro.
the VESA mount, `trinity`'s ProDesk tray and the velcro, and since
2026-10-15 the keyboard drawer and `ifrit`'s Tiny mount, both mounted.

| Item | For | Decided by | When it is needed |
| --- | --- | --- | --- |
| Four-post shelf, adjustable to 29", at least 17" deep, rated for 50 lb or more. StarTech ADJSHELFHDV fits: 19.5–38", 27.5" tray, 330 lb | `smaug` on its side, U5–U9 | [`hardware.md`](hardware.md#planned-a-32u-rack), 2026-10-12 | Before the #919 window |
| 2 × 1U four-post vented shelf, adjustable to 29" | `prometheus` U10, `oracle` U12 | [`hardware.md`](hardware.md#planned-a-32u-rack) | Before the #919 window |
| 1U sliding keyboard drawer, front-rail mount | The console, U24 | [`hardware.md`](hardware.md#planned-a-32u-rack) | Before the #919 window |
| 1U mount made for a ThinkCentre Tiny, holding its brick | `ifrit`, U18 | [`hardware.md`](hardware.md#planned-a-32u-rack) | Before the #919 window |
| 3 × 1U four-post vented shelf, adjustable to 29" | `prometheus` U10, `oracle` U12, and the KVM at U23 | [`hardware.md`](hardware.md#planned-a-32u-rack); the third on 2026-10-15 | Before the #919 window |
| 1U horizontal cable manager | U20, between switch and panel | [`hardware.md`](hardware.md#planned-a-32u-rack) | Before the #919 window |
| 1U vented blank | U22, the air gap over the CRS326 | [`hardware.md`](hardware.md#planned-a-32u-rack) | Before the #919 window |
| One factory-made Cat6 patch cable, long enough for the run | The XB7's striped 2.5G port to `morpheus`'s `em0`, replacing the hand-crimped patch | [#923](https://github.com/Gerrrt/HomeLab/issues/923) | Now: it should not wait for the move |
Expand Down
37 changes: 26 additions & 11 deletions docs/runbooks/move-into-the-32u-rack.md
Original file line number Diff line number Diff line change
Expand Up @@ -77,10 +77,10 @@ ones not yet on hand are also in the roadmap's
| --- | --- | --- |
| 32U four-post open frame, adjustable depth to at least 30" | 1 | The frame. Bought 2026-10-09, built 2026-10-11 at 29" |
| VESA 100 × 100 rack mount for a 17–19" screen (sold as 4U) | 1 | The ViewSonic N1700W, U25–U32. On hand, 2026-10-13 |
| 1U sliding keyboard drawer, front-rail mount | 1 | U24 |
| 1U mount for a Lenovo ThinkCentre Tiny, holding its power brick | 1 | `ifrit`, U18 |
| 1U sliding keyboard drawer, front-rail mount | 1 | U24. On hand and mounted, 2026-10-15 |
| 1U mount for a Lenovo ThinkCentre Tiny, holding its power brick | 1 | `ifrit`, U18. On hand and mounted, 2026-10-15 |
| 1U ProDesk Mini tray (the same one as `morpheus`'s) | 1 | `trinity`, U16. On hand, 2026-10-13 |
| 1U vented four-post shelf, square-hole, adjustable to 29" | 2 | `prometheus` U10 and `oracle` U12 |
| 1U vented four-post shelf, square-hole, adjustable to 29" | 3 | `prometheus` U10, `oracle` U12 and the KVM at U23, whose own ears are half-height ([`hardware.md`](../hardware.md#planned-a-32u-rack)) |
| Four-post shelf, adjustable to 29", at least 17" deep, rated for 50 lb or more | 1 | `smaug` on its side, U5–U9 (about 20 lb) |
| 1U horizontal cable manager | 1 | U20 |
| 1U vented blank | 1 | U22, the air gap over the CRS326 |
Expand Down Expand Up @@ -238,11 +238,14 @@ The PDU has ten outlets. Write down what will plug into it:
| CRS326 (DC adapter) | 1 |
| N1700W (12 V brick) | 1 |
| `smaug` (racked at U5–U9; the long cord is retired) | 1 |
| Both laptops' chargers | 2 |
| Both laptops' chargers | 0: on the UPS's own outlets, beside the TP-Link |

That is **9–10 of 10**. If it comes to 11, put the laptops' chargers on the
UPS's own outlets beside the TP-Link: the laptops carry their own batteries,
so they need the outlets least. Do not daisy-chain a power strip off the PDU.
That is **8–9 of 10**, by the outlet map in
[`hardware.md`](../hardware.md#console-and-power-maps). The laptops'
chargers go on the UPS's own outlets in either case: with two DL360
supplies the PDU would be at eleven, and the laptops carry their own
batteries, so they need its outlets least. Do not daisy-chain a power strip
off the PDU.

---

Expand Down Expand Up @@ -361,7 +364,7 @@ units (§1.2), then the next one up.
| 12 | U20 | Cable manager | |
| 13 | U21 | CRS326 | Already racked on 2026-10-12. [`swap-the-switch.md`](swap-the-switch.md) Phase 2, step 2 is done; carry on from step 3 |
| 14 | U22 | Vented blank | The air gap over the passive switch |
| 15 | U23 | KVM | |
| 15 | U23 | KVM, on its vented shelf | Its half-height ears take two of a unit's three holes; the shelf takes all three |
| 16 | U24 | Keyboard drawer | Front rails only |
| 17 | U25–U32 | N1700W on its VESA mount | The bracket bolts to 4U. The screen in front of it covers 8U |

Expand Down Expand Up @@ -390,9 +393,21 @@ units (§1.2), then the next one up.
it back in before `trinity` powers up in §7: it holds Immich's originals.
- **The XB7 to `morpheus`'s `em0`:** a factory cable, seated until the latch
clicks, in the XB7's striped 2.5 Gbit port.
- KVM: one lead set each to `morpheus`, `Saruman`, `trinity` and `ifrit`.
Write down which KVM port is which; the repository has no map of it. The
lead sets reach from U23 down to `Saruman` at U3, checked 2026-10-12.
- KVM: one lead set each, **by the port map in
[`hardware.md`](../hardware.md#console-and-power-maps)**: `morpheus` on 1,
`trinity` on 2, `Saruman` on 3, `smaug` on 4 if the TS150's rear VGA is
used, `ifrit` on 5. The lead sets reach from U23 down to `Saruman` at U3,
checked 2026-10-12.
- Power cords **by the PDU outlet map** in the same section: the DL360's
supplies on 1 and 2, then up the rack, the external bricks together on 6–9
and the KVM on 10. Both laptops' chargers go on the UPS's own outlets
beside the TP-Link, not on the PDU (§1.7).
- **Read which UPS outlet group the PDU's cord is on**, and which the
TP-Link and the chargers are on. The Smart-UPS X's outlets are in groups
the card can switch and sequence separately, and no document records
which group feeds what. Check each group's turn-off and turn-on settings
against ADR-0049's shutdown and §7's power-up order, and write the groups
into `hardware.md` in §8.

---

Expand Down