docs(rack): put the KVM on a shelf, decide the KVM and PDU maps, retire two bought rows - #1198

Merged
Gerrrt merged 2 commits into
mainfrom
worktree-kvm-shelf-and-console-maps
Oct 15, 2026
Merged

Gerrrt merged 2 commits into
mainfrom
worktree-kvm-shelf-and-console-maps

Conversation

@Gerrrt

@Gerrrt Gerrrt commented Oct 15, 2026

Copy link
Copy Markdown
Owner

What changed

Docs only, no change to the running lab. The KVM at U23 goes on a third 1U vented shelf, because the MT-VIKI 801UK-L is a half-U device whose ears take two of a unit's three holes and sit about 8 mm off centre either way. hardware.md gains a Console and power maps section: KVM ports in the runbook's power-up order (morpheus 1, trinity 2, Saruman 3, smaug 4 if its rear VGA is used, ifrit 5), and PDU outlets bottom of the rack up with the bricks together at the far end. The keyboard drawer and ifrit's Tiny mount, both mounted on 2026-10-15, leave Everything still to buy; twelve rows become ten, and README's count follows. The move runbook's §0.1, §6 and §6.1 say the same, and §6.1 now cables the KVM and the PDU by the maps instead of asking for them to be written down at the rack. Changelog entry dated 2026-10-15.

Why

Refs #919. The runbook asked for the KVM port map to be written down during the window; deciding it before cabling is cheaper, and the PDU map had never existed. The two stale purchase rows broke the roadmap's own rule that a bought part leaves the table.

Blast radius

None: documentation only.

  • No change to network segmentation or firewall rules
  • No new port published to a VLAN that could not already reach the service
  • No credential added outside secrets/*.sops.yaml

Verification

  • python3 scripts/check_docs.py: docs OK — 158 Prometheus + 20 Loki rules, 8 dashboards, 156 panels, 12 assertions, after the README count was corrected from eleven to ten.

  • ./scripts/lint.sh: every check PASS.

  • make validate: all checks passed (5 skipped — NOT run, not verified). The five skips are the worktree ones: the offsite path refusal (CI covers it), unit syntax, installed timers, the sensitive stack's timers and the homelab-* units, none of which this checkout serves. Lint ran without --require-all; CI runs the hardened boots, the secret scan and the close-keyword check too.

  • python3 scripts/check_close_keywords.py --text on this body: clean.

  • make validate passes

  • Deployed to the lab and confirmed working (nothing to deploy)

  • Docs updated (docs/, service README, or docs/roadmap.md)

🤖 Generated with Claude Code

…re two bought rows

The MT-VIKI 801UK-L is a half-U device: its ears take two of a unit's
three holes and sit about 8 mm off centre either way, so it goes on a
third 1U vented shelf at U23. hardware.md gains a Console and power maps
section: KVM ports in the runbook's power-up order, PDU outlets bottom of
the rack up with the bricks together at the far end. The keyboard drawer
and ifrit's Tiny mount, mounted 2026-10-15, leave Everything still to
buy; twelve rows become ten and README's count follows. The move runbook
cables the KVM and the PDU by the maps instead of asking for them at the
rack.

Refs #919.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
Copilot AI balanced review requested due to automatic review settings October 15, 2026 22:38

Copilot AI left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟡 Changes recommended

The power instructions require a nonexistent UPS main group and leave both laptop chargers unassigned.

2 open findings
What changed in this PR

This documentation-only PR prepares the 32U rack move by defining cabling maps and updating hardware and purchase records.

Changes:

  • Adds a third vented shelf for the KVM.
  • Defines KVM port and PDU outlet assignments.
  • Removes two purchased items from the roadmap and updates README’s count.
File Description
README.md Updates outstanding purchases from twelve to ten.
docs/​runbooks/​move-into-the-32u-rack.md Updates mounting, shelf requirements and cabling instructions.
docs/​roadmap.md Removes bought mounts and adds the KVM shelf.
docs/​hardware.md Records mounted parts and console/power maps.
docs/​changelog.md Records the rack-planning decisions.

🧠 Review effort: Balanced


💡 Add a code-review agent skill or configure MCP servers for context-aware, tailored reviews. Learn more in the docs.

Comment thread docs/runbooks/move-into-the-32u-rack.md Outdated
Comment thread docs/hardware.md
@Gerrrt
Gerrrt enabled auto-merge (squash) October 15, 2026 23:26
…groups, not assume a main one

Review on #1198: the PDU map omitted both laptops' chargers, which §1.7
counts, and asked for the PDU to be on a UPS "main group" that may not
exist. The chargers go on the UPS's own outlets beside the TP-Link in
either case, so the map holds whether the DL360 has one supply or two,
and §1.7's count becomes 8–9 of 10. The check now reads which outlet
group feeds the PDU, the TP-Link and the chargers, and compares each
group's switching settings with ADR-0049 and §7's power-up order.

Refs #919.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
@Gerrrt
Gerrrt merged commit 020cc55 into main Oct 15, 2026
8 checks passed
@Gerrrt
Gerrrt deleted the worktree-kvm-shelf-and-console-maps branch October 15, 2026 23:42
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

3 participants