Julia services that simulate smart-meter power flow on local hardware, write readings to PostgreSQL (AWS RDS), and expose the same data to the dashboard via a read-only Lambda API.
Most domestic smart meters have very limited computing power and thus lack the ability to perform detailed power grid analysis. The project team are working together, under the guidance of Dr. Eduardo Cotilla-Sanchez, to develop a GPU-accelerated smart meter alongside grid algorithms to allow for real-time analysis of large power grid cases. This repo is the cloud + simulation backend in that pipeline.
| Piece | Link |
|---|---|
| Smart meter dashboard (React) | rojaslesly/smartMeter |
| Landing & pipeline showcase | nikoloda/GridPing-Showcase · gridping.vercel.app |
| Backend (this repo) | Simulation, RDS writes, Lambda read API |
- Meter poller — loads MATPOWER cases, runs AC power flow (PowerModels + Ipopt), computes local/global PQ and island count, inserts into
records/globalRecords - Case tooling — generate perturbed hourly cases; audit generated and event cases for convergence
- DB helpers — peek or clear SQLite (local) or Postgres (AWS)
- Lambda — SQL queries for the dashboard (
latest_bus,bus_24h,latest_global,last_outage); does not run power flow
Simulation runs on your machine (or edge device). RDS stores rows. EC2 is only an SSH jump host for dev writes. Lambda reads RDS for the React app.
| Layer | Technology |
|---|---|
| Simulation | Julia, PowerModels, Ipopt, JuMP |
| AWS DB | RDS (PostgreSQL), LibPQ |
| Local DB | SQLite (optional) |
| API | Node.js Lambda (pg) |
| Cases | MATPOWER .m under cases/transmission/ |
Install Julia and project deps (PowerModels, Ipopt, LibPQ, etc.) as used in scripts/ and src/.
Contact nikoloda@oregonstate.edu for credentials. Place .env at the repo root (gitignored):
PGHOST=localhost
PGPORT=5433
PGUSER=______________
PGDATABASE=______________
PGPASSWORD=______________Or a single PG_CONN=... string. connect_pg() in src/DB_AWS_PostgreSQL.jl loads unset vars from .env.
RDS is not public. Open a tunnel through the bastion EC2 (region us-west-2). Get bastion public IP and RDS endpoint from the AWS console (EC2 → Instances; RDS → Databases). If SSH times out, start the EC2 instance and allow SSH (22) from your IP on its security group.
Leave this terminal open:
ssh -i /path/to/bastion-key.pem -L 5433:<rds-endpoint>:5432 ec2-user@<bastion-ip> -NVerify:
julia db_manual/peek_postgres.jlLambda in production uses DB_HOST, DB_USER, DB_PASSWORD, DB_NAME and talks to RDS directly—no tunnel.
julia scripts/meter_reading_simulator.jlDefaults: bus 6, 24 hourly steps, 45 s between readings, Postgres on (USE_AWS_POSTGRES). Toggle SQLite or timing flags at the top of the script.
Optional long-running variant: julia scripts/meter_reading_simulator_forever.jl.
Distribution poller (8500-Node, bus 293471): julia scripts/distribution_meter_reading_simulator.jl.
Distribution debug (single Master-unbal.dss solve, no loop): julia scripts/distribution_meter_reading_simulator_once.jl.
julia scripts/check_generated_case_solvability.jl
julia scripts/matpower_case_generator.jl # generate transmission cases
julia db_manual/clear_postgres_records.jl # destructive — truncates AWS tablesnotebooks/ — early experiments and prototypes (e.g. Postgres init, population); kept as artifacts, not required for the poller flow.
Implemented in lambda/index.mjs. Matches table layout from DB_AWS_PostgreSQL.jl. Query param query:
| Query | Parameters | Returns |
|---|---|---|
latest_bus |
bus_id, target_time |
Closest meter record for bus |
bus_24h |
bus_id, target_time |
Bus records in prior 24 h |
latest_global |
target_time |
Closest global grid record |
last_outage |
bus_id, target_time |
Latest outage row for bus |
target_time: YYYY-MM-DD HH:mm:ss. Response shape: { query, target_time, count, rows[] }.
bus_id values: transmission poller uses 6; distribution meter SX_293471A uses 293471 (distribution_meter_reading_simulator.jl).
Frontend PQ mapping: see frontend/gridData.js (drop-in for smartMeter src/utils/gridData.js).
Both pollers write the same field: power_quality = Δv (p.u.) = meter voltage − ideal voltage at that meter. Non-converged: -100, status = 0.
| Ideal case | bus_id |
|---|---|
case2383wp.m |
6 |
Master-unbal.dss at min diurnal loadmult |
293471 |
0–100% dial is computed in frontend/gridData.js
cases/transmission/ # MATPOWER .m — base, generated_cases/, event_cases/
db_manual/ # peek / clear SQLite or Postgres
lambda/ # Read API for dashboard
notebooks/ # Experimentation / idea testing (historical artifacts)
scripts/ # Poller, case generator, solvability audit
src/ # DB_AWS_PostgreSQL.jl, DB_SQLite.jl
OpenDSS (.dss) cases: use dss-extensions/electricdss-tst for IEEE/EPRI examples and other test circuits (filtered OpenDSS sample scripts).