docs(rack): buy a temperature probe for the UPS card, a switched PDU and eight accessories - #1202
Merged
Merged
Conversation
Decided by the operator on 2026-10-16. The AP9641 card has a sensor port and nothing measures rack ambient, so an APC AP9335T probe joins Everything still to buy; the existing SNMP job polls the card, and a generator change follows the purchase. The 10-outlet strip gives way to a switched, SNMP-managed PDU of the APC AP7900B class, because four hosts have no BMC and a hung one needs someone at the rack. Eight outlets suffice once the screen's brick and the KVM move to the UPS's own outlets. The PDU is a management-plane device: its segment and hardening are an ADR before it is cabled, and hardware.md says the outlet map is the strip's until then. Ten rows become twelve, README follows. Refs #919. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
Decided by the operator on 2026-10-16, one row each so each leaves as it arrives: a USB-to-RJ45 console cable for the CRS326, labels for every lead and port, a stick-on rack light, a bonding strap for the frame, a basic cable tester, power-side cable management, levelling feet if the floor needs them, and a tenkeyless keyboard that fits the 10.8" drawer. None gates the move; the runbook fits whichever have arrived. Twelve rows become twenty, README follows. Refs #919. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
There was a problem hiding this comment.
🟢 Approval recommended
The documentation-only changes have no blocking issues; the remaining timing clarification is minor.
1 open finding
What changed in this PR
Records ten planned purchases for the rack upgrade, without changing the running lab.
Changes:
- Adds a temperature probe, switched PDU and eight accessories.
- Updates the purchase count from 10 to 20.
- Documents optional accessory installation and the PDU’s prerequisite architecture decision.
| File | Description |
|---|---|
| README.md | Updates the outstanding purchase count. |
| docs/runbooks/move-into-the-32u-rack.md | States accessories do not gate the move. |
| docs/roadmap.md | Adds ten purchase rows and timing. |
| docs/hardware.md | Describes probe and PDU plans. |
| docs/changelog.md | Records the purchase decisions. |
🧠 Review effort: Balanced
💡 Add a code-review agent skill or configure MCP servers for context-aware, tailored reviews. Learn more in the docs.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.

What changed
Docs only, no change to the running lab. Two purchases and eight accessories join Everything still to buy, decided by the operator on 2026-10-16: an APC AP9335T temperature probe for the UPS's AP9641 card, and a switched, SNMP-managed 1U PDU of the APC AP7900B class to replace the 10-outlet strip. Eight accessories join as well, one row each: a serial console cable for the CRS326, labels, a rack light, a bonding strap, a cable tester, power-side cable management, levelling feet and a tenkeyless keyboard for the 10.8" drawer. Ten rows become twenty and README's count follows; the move runbook says none of the accessories gates the window.
hardware.md's console-and-power section says the outlet map is the strip's and is redrawn when the switched PDU is placed, and that the PDU's segment and hardening are an ADR before it is cabled. Changelog entry dated 2026-10-16.Rebased onto main after #1200 merged; the branch carries only these two commits.
Why
Refs #919. Nothing measures rack ambient, and the card has the port for it. Four hosts have no BMC (
morpheus,trinity,ifrit,smaug), so a hung one needs someone at the rack; a switched PDU is the remote power path the KVM cannot give. Eight outlets suffice once the screen's brick and the KVM move to the UPS's own outlets. The roadmap's rule is that a purchase enters only on the operator's decision, in the PR that records it.Blast radius
None: documentation only. The PDU itself is a later change with its own ADR.
secrets/*.sops.yamlVerification
python3 scripts/check_docs.py:docs OK — 158 Prometheus + 20 Loki rules, 8 dashboards, 156 panels, 12 assertions(the purchase count is among the assertions)../scripts/lint.sh: every check PASS.make validate:all checks passed (5 skipped — NOT run, not verified)on the second run. The first run failedlab: promtool check configwhile promtool itself printed success, the known local flake under a busy shared docker daemon; the rerun was clean. The five skips are the worktree ones: the offsite path refusal (CI covers it), unit syntax, installed timers, the sensitive stack's timers and the homelab-* units, none of which this checkout serves. Lint ran without--require-all; CI runs the hardened boots, the secret scan and the close-keyword check too.python3 scripts/check_close_keywords.py --texton this body: clean.make validatepassesDeployed to the lab and confirmed working (nothing to deploy)
Docs updated (
docs/, service README, ordocs/roadmap.md)🤖 Generated with Claude Code